Change Filename after acquisition? by Garrett Deletti | 0 CommentsWhen using SciexOS software analytics application:
Relative migration time by Rahima Danishmand | 0 CommentsHow do I set up my processing method to calculate the RRT of the main peak to 10kD in karat 32 software?
What mobile phases can be used with the PFAS Free LC Kit? by Arielle Cocozza | 0 CommentsI have a Exion LC AD fitted with the Exion LC AC PFAS kit – I’m looking into running another application on the instrument alongside PFAS analyses that uses 0.2% Formic Acid in H2O as one of the mobile phases. I can’t find any literature on whether the components in the kit are compatible with a formic acid solution as the mobile phase. Has anyone had experience running with this MP on this kit?
Change Filename after acquisition? by Garrett Deletti | Other, QTRAP / Triple Quad, Questions, SCIEX OS softwareWhen using SciexOS software analytics application:
Relative migration time by Rahima Danishmand | CE, QA/QC, Questions, SCIEX OS softwareHow do I set up my processing method to calculate the RRT of the main peak to 10kD in karat 32 software?
What mobile phases can be used with the PFAS Free LC Kit? by Arielle Cocozza | LC, Other, Questions, SCIEX OS softwareI have a Exion LC AD fitted with the Exion LC AC PFAS kit – I’m looking into running another application on the instrument alongside PFAS analyses that uses 0.2% Formic Acid in H2O as one of the mobile phases. I can’t find any literature on whether the components in the kit are compatible with a formic acid solution as the mobile phase. Has anyone had experience running with this MP on this kit?
Sciex OS – report automatically opens by Henriette Krenkel | Other, QTRAP / Triple Quad, Questions, SCIEX OS softwareHi,
Error when saving result table Analyst 1.7.3 by WuXi AppTec | LC, Other, QuestionsWhen saving data or result table to a network share
High mass tuning calibration for ZenoTOF 7600 by Gregg Czerwieniec | Bio Tool Kit, Development, Questions, ZenoTOF 7600 systemHi,
Jon MacGregor by Jon MacGregor | Ion sources, Other, Questions, ToxicologyI have a turbo v ion source that shows a glowing blue/purple light at the tip of the Heated Nebulizer corona discharge needle, even when it is not in use and turned out of ion path as it should be when using TIS probe. It only happens in negative mode. It is not arcing to the cutain plate, just a slight noticeable glow at the tip of the corona needle when observed through the front window. My FSE has rebuilt the HN probe and components and also installed a new TIS probe. Still glows when in negative mode. Note also having poor sensitivity in negative mode as well and jagged peak shapes during infusion. Any ideas? Are the symptoms related?
Limit on the number of elements in untargeted workflow–”Formula Finder Section” by 强 张 | Metabolomics, Other, Questions, SCIEX OS softwareHow can I limit the minimum number of elements for formula searching in sciex os non-target data processing procedure? I need a range and not just the maximum number of elements.
SCIEX OS software analytics – Change default folder for reports by Henriette Krenkel | Other, Questions, SCIEX OS softwareWhen using Sciex OS for data processing, the reports created in the analytics module are by default saved into C:\ProgramData\SCIEX\Analytics\Reporter\Reports. How can this default folder be changed?
Does SCIEX provide APIs? by 显顺 汪 | Questions, SCIEX OS softwareWhere I can get the API of the software?
calibration using sum of peak areas vs concentration by Andrew Charlton | Data processing, QTRAP / Triple Quad, Questions, SCIEX OS softwareHi,
Source optimization by Trang Nguyen | Ion sources, Optimizing Performance, QTRAP / Triple Quad, Questions, SCIEX OS softwareHello. I am setting up a new development method for analyzing toxic chemicals.
Reporting only unknown samples containing a specific sample ID prefix (in this case Sample ID prefix = PHT) by Steven McGuire | Data processing, QTRAP / Triple Quad, Questions, SCIEX OS softwareI am using Multiquant software and I am trying to create a report to pull data on specific sample from a large run.
Baseline Dip using PA800 Plus SDS-MW Application by Priya Patel | CE, Development, Questions, SCIEX OS softwareWe’ve noticed that with some gel buffer lots, we see a dip in the baseline at 280 nm when analyzing proteins per the SDS-MW protocol. Has anyone experienced this before? We don’t always see it and are wondering what causes the dip.
N-Methyl Pyrollidone by Suresh Narayanasamy | Development, Pharma, QTRAP / Triple Quad, QuestionsI am in the process of analyzing nitrosamines using QTRAP. One of the difficulties in my sample preparation would be using NMP as solvent to dissolve the material. Is it safe to inject approximately 10ul of NMP is QTRAP??
Please provide at least 3 decimal places for expected retention time for scheduled MRM at EchoMS by Riyo Imamura | Data acquisition, Echo® MS+ system, Questions, SCIEX OS software, TechnologyExpected retention time for scheduled MRM at EchoMS must have at least 3 decimal places, because the minute display with two decimal places is insufficient to show the difference in seconds. Thank you.
Processing ZenoTOF data using the Human Pan-Human library from Swath Atlas (phl004_canonical_s32_osw.csv) and DIANN by Pedro Magalhães | Other, Proteomics, Questions, ZenoTOF 7600 systemHello,
Standard peaks are noisy by Vasu Medikonda | Industrial, QTRAP / Triple Quad, Questions, SCIEX OS softwareI am Using Sciex Qtrap 4500 for quantification of nitrosamines (NDMA&NDBA). I am facing issue with higher baseline intensity. When developed the method in APCI the basline was at about 5e4. but now even after cleaning the source (i.e. Changed capillary to new, Curtain plate & Corona needle cleaning, given blank injection overnight ), my base line decreased from 1e6 to 4 e5, but settled at 4 e5 from past 24 hours. can you suggest me how decrease my baseline intensity further to below 1e5. My standard peaks are like noise now.
Loss the contact closure signal by amornmart jaratrungtawee | Proteomics, QTOF, Questions, SCIEX OS softwareour 7600 couple with nanoLC Ultimate 3000 via contact closure. it has run without any loss connection during the batch. Just yesterday, the last injection keep equilibrating system until the LC finished the gradient run. We closed the software and power off LC and MS then started again but it did not help. The Dionex engineer also checked their LC and triggerring cable found both are ok.
General question on SCIEX 7500 by Dhayaalini Nadarajan | Data acquisition, Ion sources, Questions, SCIEX OS software, TechnologyGood morning.
Library database file types imported into LibraryView™ by 强 张 | Agriculture, CE, Questions, SCIEX OS softwareAs is stated in official guidance, many different types of compound and library databases can be imported into LibraryView™ software, such as Excel file (*.xls) and Third Party Library Package (*.tplp). Can somebody tell me what's the format like "tplp", which is so...
Dynamic Window Extension in SCIEX OS by Jimmy Murillo Gelvez | Data acquisition, Other, Questions, SCIEX OS software, TechnologyHello,
Protein Pilot Cysteine Modification by Matt Schnell | ProteinPilot, Proteomics, QTOF, QuestionsHello,
Can Resolution value be a zero? by Deokheon Song | Biopharma, CE, Questions, ResultsCan Resolution value be a zero?
I want to use the Discovery Quant function at EchoMS by Riyo Imamura | Discovery, Echo® MS+ system, Questions, SCIEX OS softwareI think EchoMS is powerful tool for high-throughput MS and it would be even better if the Discovery Quant function could be used in SCIEX-OS. I think it will be possible by using the infusion mode.
SCIEX Software support for beyond Win10 by Tatiana Perez | QuestionsSCIEX does not support their instruments on windows 10 version 20H2 or above (including Windows 11).